Skip to main content
The new name for DisabledGo

Quad North

Brunel University London, Uxbridge Campus, Kingston Lane, London, UB8 3PH

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Overview

Getting Inside

  • The approach to the building varies depending on which direction you come from. There is step-free level access and also varying degrees of slopes.
  • The step-free approach to the building is from the west side of campus and also the building's parking area.
    The approach with slopes is from the southeast side of campus.
  • Quad North has four entrances. The most accessible is the entrance on the northwest side of the building by the car park.
  • The accessible entrance is signed accessible entrance.
    The southeast entrance is signed 'Chemical Engineering'.
    The northeast entrance is not signed.
    The southwest entrance is signed 'Brunel Medical School, Psychology, Chemical Engineering'.
  • The accessible entrance provides step-free access with a slight slope to the east wing ground floor corridor leading to the foyer.
  • The southeast entrance has sloped access to the ground floor foyer. The northeast entrance has sloped access to the ground floor foyer. The southwest entrance has stepped access to the first floor lobby.

Getting Around

  • There is step-free level access throughout the building via lifts.
  • Access to teaching room 055 is via steps or a platform lift on the ground floor.
    Access to the Graduate School reception is via five steps or a platform lift on the first floor.
  • Floor surfaces along circulation routes are hard and smooth or carpeted and smooth.
  • There are resting areas in the ground floor foyer and first floor central lobby area with a mixture of seating.
  • Wall mounted wayfinding signage is provided throughout the building.
  • There are some automatic and manual doors to access corridors, lobbies and stairwells.

Toilet and Changing Facilities

  • Toilet Facilities View
    • There are 7 toilets with adaptations.
    • Toilets with adaptations are located on each floor within the lobby areas and corridors.
    • The transfer space varies between left and right in the toilets with adaptations.
    • Ambulant toilet facilities are located within the standard male and female toilets on each floor.
    • The male and female step-free toilet facilities are located on each floor within the lobby areas and corridors.
    • The along the West Corridor of Chemical Engineering step-free toilet facilities are located gender inclusive.
  • Washroom and Shower Facilities View
    • The shower facilities which have adaptations are located within the west corridor of Chemical Engineering on the ground floor.

Rooms and Services in the Building

Parking (Quad North)

  • Car Park View
    • The car park is located at the rear of Quad North on the North Loop Road.
    • The car park is open air/surface.
    • The car park surface consists of concrete.
    • There are 2 designated Blue Badge parking bays available.
    • The Blue Badge bays are clearly marked.
    • The surveyed Blue Badge parking bay dimensions are 260cm (width) x 470cm (depth).
    • There is a marked zone to both sides and rear.
    • The width of the marked zone is 110cm.
    • The nearest designated bay is 13m from the accessible entrance.
    • The most accessible route from the Blue Badge parking has slight ramps or slopes.
  • Charges and Restrictions View
  • Drop-off Point View
    • There is not a designated drop-off point available.
  • Public Car Parks View
    • The Campus Car Park is the nearest other parking within the Campus.

Campus Car Park

  • Car Park View
    • The car park is located along the Campus North Loop Road.
    • The car park is open air/surface.
    • The car park surface consists of tarmac.
    • There are 9 designated Blue Badge parking bays available.
    • The Blue Badge bays are clearly marked.
    • The surveyed Blue Badge parking bay dimensions are 240cm (width) x 470cm (depth).
    • There is a marked zone to one side but not at the rear.
    • The width of the marked zone is 120cm.
    • There is a dropped kerb with tactile paving from the designated Blue Badge parking.
    • The nearest buildings to the car park are the Biology Annexe, Howell, the Design and Print Service (Press Building), the Heinz Wolff building, Bragg and Quad North.
    • This car park is also the nearest with Blue Badge parking bays for the Lecture Centre.
  • Charges and Restrictions View
  • Drop-off Point View
    • There is not a designated drop-off point available.

Entrance (Accessible)

  • This entrance is located on the south side of the building by the Quad North car park.
  • The entrance area is clearly signed.
  • There is not a canopy or recess which provides weather protection at the entrance.
  • There is step-free access via slope at the entrance.
  • The slope has a slight gradient.
  • There are double automatic doors at this entrance.
  • The doors open towards you.
  • There is a push pad at a height of 82cm.
  • The width of the opening is 162cm.
  • There is a small lip on the threshold of the opening.
  • The doors have a high visual contrast.
  • There is a push pad or push button to exit at a height of 84cm.
  • There is step-free level access as you enter.

Lift (Main)

  • The lift surveyed is located in the foyer of Quad North.
  • The distance from the accessible entrance is 31m.
  • The most accessible route to the lift has manual doors and step-free level access.
  • The ground, first and second floors are accessed by this lift.
  • The lift door has a high visual contrast.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The weight limit for the lift is 1500kg.
  • The external lift control buttons have tactile markings and a high visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 106cm.
  • The internal dimensions of the lift are 168cm (width) x 170cm (depth).
  • The internal lift control buttons have tactile markings and a high visual contrast.
  • All of the internal lift controls are at a suitable height for a wheelchair user.
  • Internally the lift has: a mirror to aid reversing, a visual floor indicator and an audible announcer.
  • Lighting levels were low at the time of the survey.

Stairs

  • The stairs surveyed are located in the foyer of Quad North.
  • The ground, first and second floors can be accessed by these stairs.
  • There are 20 steps between floors.
  • The steps are unmarked and have handrails on both sides.
  • The handrails are not easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails do not extend horizontally beyond the first and last step.
  • The height of the steps is between 15cm and 18cm .
  • The height of the highest step is 17cm.
  • The depth of the steps is not between 30cm and 45cm.
  • Lighting levels were even at the time of the survey.

Lift (Platform)

  • The lift surveyed is located in the foyer of Quad North.
  • This lift is a platform lift.
  • The distance from the accessible entrance is 39m.
  • The most accessible route to the lift has automatic doors and step-free level access.
  • The ground floor foyer and teaching room 055 are accessed by this lift.
  • The lift door has a low visual contrast.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The weight limit for the lift is 300kg.
  • The external lift control buttons have tactile markings and a high visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 80cm.
  • The internal dimensions of the lift are 80cm (width) x 142cm (depth).
  • The internal lift control buttons have a high visual contrast and tactile markings.
  • All of the internal lift controls are at a suitable height for a wheelchair user.
  • The button needs to be pressed constantly when in use.
  • Internally the lift has: a separate door to exit.
  • Lighting levels vary due to the size of the space.

Shower with Adaptations

  • Location and Access View
    • The shower surveyed is located along the west corridor of Chemical Engineering.
    • The distance from the Chemical Engineering entrance is 14m.
    • The most accessible route to the shower has step-free level access and automatic doors.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a low visual contrast.
    • The width of the door opening is 86cm.
    • The door has a locking handle.
    • Internally the door has a low visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • There is room for a wheelchair user to manoeuvre in the shower (150cm x 150cm).
    • There is an adjustable shower head which can also be detached.
    • The shower controls are push.
    • There is a flip-down shower seat.
    • The shower seat is 48cm from the floor.
    • There are grab rails and dropdown rails for the shower.
    • The grab rails have a high visual contrast.
    • The dropdown rails have a high visual contrast.
    • There is no emergency alarm for the shower.
    • There is a full length mirror.
    • There is no shelf.
    • The facility has no disposal facilities.
    • There are multiple coat hooks.
    • The coat hooks are 105cm and 140cm from the floor.
    • The walls and floor have a high visual contrast.
    • Lighting levels were even at the time of the survey.

Toilet with Adaptations (Ground Floor - Left Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located at the rear of the main foyer of Quad North.
    • The distance from the accessible entrance is 32m.
    • The most accessible route to the toilet has step-free level access and manual doors.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 84cm.
    • The door has a locking handle.
    • Internally the door has a low visual contrast.
    • There is not a grab rail on the internal door .
  • Dimensions and Features View
    • The dimensions of the cubicle are 158cm (width) x 221cm (depth) and there is room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
    • The lateral transfer space is 94cm (from the side of the toilet pan).
    • There is a spatula flush on the non-transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a high visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a high visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 48cm from the floor.
    • The toilet seat has a low visual contrast.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a low visual contrast.
    • The toilet roll holder is 96cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 72cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a high visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 90cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a high visual contrast.
    • The hand dryer is 90cm from the floor.
    • There is a pull cord emergency alarm within 10cm from the floor.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a nappy/incontinence items bin.
    • There are no coat hooks.
    • The walls and floor have a high visual contrast.