Skip to main content
The new name for DisabledGo

Kingston Business School

Kingston Hill Campus, Kingston Hill, Kingston upon Thames, Surrey, KT2 7LB

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Introduction

  • Services / facilities within the building include teaching rooms, meeting rooms and staff offices.
  • The most accessible entrance is the main entrance.
  • As Kingston Hill Campus is situated on a hillside, step-free access via the other entrances may require some significant route finding around the campus.

Getting Here

Useful Information

Location of Toilet/Changing Facilities

  • Accessible toilet facilities are located to the left and right-hand sides of the building on all floors.
  • Female and male standard toilet facilities are located to the left-hand side of the building on all floors.
  • Parent and baby changing facilities are located on the ground floor, within the toilet with adaptations to the right-hand side of the building, within the lift lobby.

Site/Campus Car Park (Car Park G)

  • Car Park View
    • The car park is located towards the east of the site, follow signs for Halls of Residence.
    • The nearest building(s) to this car park is/are Kenry House, the Education Building, and the Terrace Building.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is tarmac.
    • Designated Blue Badge parking bays are available.
    • The Blue Badge bay(s) is/are clearly marked.
    • There is/are 6 designated Blue Badge parking bay(s) within this car park.
    • The dimensions of the designated parking bay(s) are 350cm x 560cm (11ft 5in x 18ft 4in).
    • The dimensions of the designated bays do vary in size.
  • Charges and Restrictions View
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is step-free access to the north side of Kenry House.
      There is step-free access via lift to the south side of Kenry House, the Terrace Level of the Education Building, and the Terrace Building.
      There is step-free level access to the Education building main entrance.

Outside Access (Main Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • There is a key card reader at this entrance placed at 115cm high which is only required when the building is closed.
    • There are two sets of identical automatic doors side-by-side at this entrance.
    • There is step free access at this entrance.
    • There is a bell/buzzer.
    • The height of the bell/buzzer is 117cm (3ft 10in) .
    • There is an intercom.
    • The height of the intercom is 130cm (4ft 3in) .
    • There is a canopy or recess which provides weather protection at this entrance.
    • The main door(s) open(s) automatically.
    • The door(s) is / are double.
    • The width of the door opening is 134cm (4ft 4in).
    • There is a small lip on the threshold of the entrance, with a height of less than 2cm.
  • Second Set of Doors View
    • There is a second set of doors.
    • The door(s) open(s) automatically.
    • The door(s) is / are double.
    • The width of the door opening is 131cm (4ft 3in).
    • There is a small lip on the threshold of the entrance, with a height of less than 2cm.

Outside Access (Lawley Lecture Theatre)

  • Entrance View
    • This information is for the entrance located on the left-hand side of the building, next to the Lawley Lecture Theatre.
    • This entrance gives access to the ground floor via a stairwell lobby.
    • The entrance area/door is not clearly signed.
    • There is ramped/sloped or stepped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • There is a dark mat or floor marking at this entrance that might be perceived as a hole.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is an intercom.
    • The height of the intercom is 117cm (3ft 10in) .
    • A key card is required for access at this entrance.
    • The height of the key card reader is 120cm.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 113cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • The ramp/slope is located on the left facing the entrance.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on the right going up the ramp.
    • The ramp/slope does bypass the step(s).
    • There is a further slope located after the entrance.
    • The gradient of the slope is slight.
    • There is a level landing at the top of the slope.
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 2 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 16cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).

Outside Access (First Floor)

  • Entrance View
    • This information is for the entrance located on the first floor, to the left of the building.
    • There is step free access at this entrance.
    • There is a bell/buzzer.
    • The height of the bell/buzzer is 118cm (3ft 10in).
    • There is an intercom.
    • The height of the intercom is 132cm (4ft 4in).
    • A key card is required for access at this entrance.
    • The height of the card reader/lock is 115cm (3ft 9in).
    • There is a canopy or recess which provides weather protection at this entrance.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is / are double (with one leaf locked).
    • The door(s) is / are heavy.
    • The width of the door opening is 108cm (3ft 7in).
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Second Set of Doors View
    • There is a second set of doors.
    • The door(s) open(s) towards you (pull).
    • The door(s) is / are single.
    • The door(s) is / are heavy.
    • The width of the door opening is 108cm (3ft 7in).

Outside Access (First Floor - Alternative)

  • Entrance View
    • This information is for the entrance located on the first floor to the right of the building.
    • There is ramped/sloped or stepped access at this entrance.
    • There is a bell/buzzer.
    • The height of the bell/buzzer is 122cm (4ft).
    • There is an intercom.
    • The height of the intercom is 137cm (4ft 6in).
    • A key card is required for access at this entrance.
    • The height of the card reader/lock is 120cm (3ft 11in).
    • There is a canopy or recess which provides weather protection at this entrance.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is / are single.
    • The door(s) is / are heavy.
    • The width of the door opening is 100cm (3ft 3in).
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • There is a ramp/slope at this entrance.
    • The ramp/slope is located in front of the entrance.
    • The ramp/slope does bypass the step(s).
    • The ramp/slope gradient is slight.
    • The ramp is permanent.
    • There is a level landing at the top of the ramp.
    • The ramp does not have handrails.
  • Step(s) View
    • There is a / are step(s) at this entrance.
    • The step(s) is / are located in front of the entrance.
    • There is / are 4 step(s) to access the entrance.
    • There is tactile paving at the top and bottom of the step(s).
    • The step(s) is / are clearly marked.
    • The step(s) is / are shallow (2cm - 10cm).
    • The steps do have handrails.
    • The handrails are on both sides.

Outside Access (Second Floor)

  • Entrance View
    • This information is for the entrance located on the second floor, at the rear of the building.
    • There is ramped/sloped or stepped access at this entrance.
    • There is a bell/buzzer.
    • The height of the bell/buzzer is 123cm (4ft).
    • There is an intercom.
    • The height of the intercom is 138cm (4ft 6in).
    • A key card is required for access at this entrance.
    • The height of the card reader/lock is 121cm (3ft 12in).
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is / are single.
    • The door(s) is / are heavy.
    • The width of the door opening is 101cm (3ft 4in).
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • There is a ramp/slope at this entrance.
    • The ramp/slope is located in front of the entrance.
    • The ramp/slope does bypass the step(s).
    • The ramp/slope gradient is steep.
    • The ramp is permanent.
    • There is a level landing at the top of the ramp.
    • The ramp does have handrails.
    • The handrails are on both sides.
    • The width of the ramp is 148cm (4ft 10in).
  • Step(s) View
    • There is a / are step(s) at this entrance.
    • The step(s) is / are located in front of the entrance.
    • There is / are 4 step(s) to access the entrance.
    • There is tactile paving at the top and bottom of the step(s).
    • The step(s) is / are not clearly marked.
    • The step(s) is / are medium height (11cm - 17cm).
    • The steps do have handrails.
    • The handrails are on both sides.
  • Comments View
    • The ramp and steps lead down to the bridge leading to this entrance.

Getting Around

  • Access View
    • There is step free access throughout the building.
    • There are no doors in corridors which have to be opened manually.
  • Getting Around View
    • There is clear signage for building facilities/areas in the foyer/reception area.
    • There is clearly written and pictorial directional signage at key points of circulation routes.
    • There is some flooring in corridors which is shiny and could cause issues with glare or look slippery to some people.
    • There is high visual contrast between the walls and floor in all areas.
    • The lighting levels are good.
    • This building does not play background music.
    • There is not a hearing assistance system.

Lift

  • There is a lift for public use.
  • The lift is located to the right of the building.
  • The lift is a standard lift.
  • The floors which are accessible by this lift are G, 1, 2, 3, and 4.
  • Wall mounted information boards are provided at lift landings.
  • The weight limit for the lift is 630kg.
  • The lift is approximately 9m (29ft) from the main entrance.
  • Staff do not need to be notified for use of the lift.
  • The clear door width is 90cm (2ft 11in).
  • The dimensions of the lift are 110cm x 140cm (3ft 7in x 4ft 7in).
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The lift does not have a hearing enhancement system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The controls for the lift are within 90cm - 120cm from the floor.
  • The lighting level in the lift is moderate to good.
  • There are push pad operated double doors to access the lift lobby on the ground floor.
  • There are manual, double doors which may be difficult to open to access the lift lobby from the first floor upwards.

Other Floors (Atrium)

  • Steps View
    • The floors which are accessible by stairs are G, 1.
    • The stairs are located in the main atrium of the building.
    • The stairs are approximately 15m from the main entrance.
    • There are 15+ steps between floors.
    • The lighting levels are medium.
    • The steps are clearly marked.
    • The steps are medium height (11cm - 17cm).
    • The steps do have handrails.
    • The steps have a handrail on both sides.
    • There is a landing.

Other Floors (All Floors)

  • Steps View
    • The floors which are accessible by stairs are G, 1, 2, 3 and 4.
    • The stairs are located to the right of the building, past the lift lobby.
    • The stairs are approximately 15m from the main entrance.
    • There are 15+ steps between floors.
    • There are manual, single doors which may be difficult to open to access the stairwell on all floors.
    • The lighting levels are moderate to good.
    • The steps are clearly marked.
    • The steps are medium height (11cm - 17cm).
    • The steps do have handrails.
    • The steps have a handrail on both sides.
    • There is a landing.
    • There is a similar set of stairs to the left of the building.
    • These stairs are approximately 40m from the main entrance.

Standard Shower

  • Shower facilities are available.
  • The shower(s) surveyed is/are located on the first floor, to the left of the building, near the female and male standard toilets.
  • There is level access to the services from the shower facilities.
  • There is a deep step to access the shower cubicle.

Toilet with Adaptations (Ground Floor - Right of Building - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located to the right of the building within the lift lobby on the ground floor.
    • This accessible toilet is approximately 15m (49ft) from the main entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards (automatically).
    • The door is push pad or push button activated.
    • The push pad or push button is 100cm from floor level.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 86cm (2ft 9in).
    • The visual contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 145cm x 218cm (4ft 9in x 7ft 1in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are moderate to good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 77cm (2ft 6in).
    • The transfer space is obstructed by a sanitary bin and a waste disposal bin.
    • There is a flush, however it is not on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) and wall is high.
    • The visual contrast between the walls and floor is high.
    • There is an emergency alarm .
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are sanitary and nappy/incontinence items bin disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is not a shelf within the accessible toilet.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 47cm (1ft 6in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 110cm (3ft 7in).
    • The visual contrast between the toilet roll holder and the wall is medium.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 72cm (2ft 4in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is high.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 85cm .
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer requires hands to be inserted into the top.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 84cm (2ft 9in) .
    • The visual contrast between the hand dryer and the wall is medium.
  • Baby Changing Facilities View
    • Baby changing facilities are located within the accessible toilet.
    • There is a flip down baby change table available .
    • The height of the baby change table is 84cm.

Toilet with Adaptations (All Floors - Right of Building - Variations)

  • There are similar accessible toilets to the right-hand side of the building on the first, second, third, and fourth floors.
  • The facilities on the first, second, and third floors are within the lift lobby.
  • The facility on the fourth floor is next to the lift lobby, in the stairwell.
  • This facilities on the first, second, third, and fourth floors are approximately 2m from the lift.
  • The facilities on the first, second, third, and fourth floors each have manual doors which are easy to open.
  • The facilities on the first, second, third, and fourth floors do not have a baby change table.
  • The facilities on the first and third floors have a lateral transfer space on the right.
  • The facilities on the first, second and third floors have a coat hook which is 138cm high.

Toilet with Adaptations (Ground Floor - Left of Building - Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located on the ground floor, to the left of the building.
    • This accessible toilet is approximately 30m (98ft) from the main entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 86cm (2ft 9in).
    • The visual contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is medium.
  • Toilet Features View
    • The dimensions of the accessible toilet are 154cm x 231cm (5ft 0in x 7ft 6in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are moderate to good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 85cm (2ft 9in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is medium.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) and wall is medium.
    • The visual contrast between the walls and floor is high.
    • There is an emergency alarm .
    • The emergency pull cord alarm is fully functional.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is not a shelf within the accessible toilet.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 48cm (1ft 6in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 111cm (3ft 7in).
    • The visual contrast between the toilet roll holder and the wall is medium.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 72cm (2ft 4in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is medium.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 87cm .
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer requires hands to be inserted into the top.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 83cm (2ft 8in) .
    • The visual contrast between the hand dryer and the wall is high.

Toilet with Adaptations (First Floor - Left of Building - Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located on the first floor, to the left of the building.
    • This accessible toilet is approximately 30m (98ft) from the lift.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is easy to open.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 87cm (2ft 10in).
    • The visual contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 158cm x 216cm (5ft 2in x 7ft 1in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are moderate to good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 104cm (3ft 4in).
    • The transfer space is obstructed by a sanitary bin and a waste disposal bin.
    • There is a flush on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is medium.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) and wall is medium.
    • The visual contrast between the walls and floor is high.
    • There is an emergency alarm .
    • The emergency pull cord alarm is fully functional.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are sanitary and general waste (with lid) disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is not a shelf within the accessible toilet.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 47cm (1ft 6in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 103cm (3ft 4in).
    • The visual contrast between the toilet roll holder and the wall is medium.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 73cm (2ft 4in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is medium.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 84cm .
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer requires hands to be inserted into the top.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 83cm (2ft 8in) .
    • The visual contrast between the hand dryer and the wall is medium.

Generic (Toilet with Adaptations (All Floors - Left of Building - Variations)

  • There are similar accessible toilets to the left-hand side of the building on the second, third, and fourth floors.
  • The facilities on these floors are approximately 35m from the lift.

Standard Toilet(s)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located on the ground floor, to the left of the building.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 24m from the main entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial and written text signage on or near the toilet door.
    • It was not possible to access the female toilet.
    • An ambulant toilet cubicle is available.
    • There are horizontal wall mounted rails available on both sides of the toilet.
    • The ambulant toilet does not have vertical wall mounted grab rails.
    • The height of the wash basin(s) is 83cm.
    • The wash basin(s) tap type is push.
    • Lighting levels are good.
  • Toilet Facilities 2 View
    • The female and male toilets are located on all floors from the first floor upwards.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 32m from the lift.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial and written text signage on or near the toilet door.
    • It was not possible to access the female toilet.
    • An ambulant toilet cubicle is available.
    • There are horizontal wall mounted rails available on both sides of the toilet.
    • The ambulant toilet does not have vertical wall mounted grab rails.
    • The height of the wash basin(s) is 83cm.
    • The wash basin(s) tap type is push.
    • Lighting levels are moderate to good.