Toilet and Changing Facilities

Parking

  • Car Park View
    • The car park is located underneath the building, accessed from the rear of the building by Sheffield Interchange.
    • The car park is underground.
    • The car park surface consists of tarmac.
    • The height of the restriction barrier is 220cm.
    • There are 8 designated Blue Badge parking bays available.
    • The Blue Badge bays are clearly marked.
    • The surveyed Blue Badge parking bay dimensions are 251cm (width) x 457cm (depth).
    • There is a marked zone to both sides and rear.
    • The width of the marked zone is 130cm.
    • The nearest designated bay is 11m from Car Park Entrance - Right of Building.
    • The most accessible route from the Blue Badge parking has step-free level access and a very easy slope.
  • Charges and Restrictions View
    • This car park is for Blue Badge holders, visitors and staff permit holders only.
    • Parking is free for all users.
  • Drop-off Point View
    • There is not a designated drop-off point available.
  • Public Car Parks View
    • There is a public car park located off Arundel Gate.
    • The name of the car park is Arundel Gate Car Park.
    • Designated Blue Badge parking bays are available in the car park.

Entrance (Main Entrance)

  • This entrance is located at the front of the building, off Concourse Way. It is accessed via Harmer Lane (to the south) or Pond Hill (to the north).
  • The approach to the entrance has uneven surfaces and bollards.
  • The entrance area is not clearly signed.
  • There is a canopy or recess which provides weather protection at the entrance.
  • There is step-free access via ramp at the entrance.
  • The ramp has a steep gradient.
  • The ramp is over 150cm wide with no handrails.
  • The ramp bypasses the steps.
  • There are 15 steps with handrails on both sides.
  • The handrails are easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails do not extend horizontally beyond the first and last step.
  • The steps are clearly marked.
  • The steps have tactile markings at the top and bottom.
  • The height of the steps is between 15cm and 18cm.
  • The height of the highest step is 15cm.
  • The depth of the steps is between 30cm and 45cm.
  • There is a single automatic door at this entrance.
  • The door is permanently held open.
  • There is a push pad at a height of 85cm.
  • The width of the opening is 99cm.
  • There is a small lip on the threshold of the opening.
  • The door has a low visual contrast.
  • There is a push pad or push button to exit at a height of 89cm.
  • There is a manual revolving door next to the automatic door which can be used as an alternative route into the building. It has a width of 95cm.
  • There is step-free level access as you enter.

Entrance (From Car Park - Right of Building)

  • This entrance is located diagonally to the right as you enter the underground car park.
  • The entrance area is clearly signed.
  • There is step-free access via a very easy slope at the entrance.
  • There is an intercom at a height of 102cm.
  • There is a key fob/card reader at a height of 112cm.
  • There is a single manual door at this entrance.
  • The door has a locked extension leaf.
  • The locked extension leaf can be opened on request.
  • The door opens away from you.
  • The width of the opening is 87cm.
  • The door has a high visual contrast.
  • There is a push pad or push button to exit at a height of 115cm.
  • There is step-free level access as you enter.
  • This entrance gives access to level -1.

Entrance (From Car Park - Left of Building)

  • This entrance is located to the right and then to the left as you enter the underground car park.
  • The entrance area is not clearly signed.
  • There is step-free level access at the entrance.
  • There is an intercom at a height of 116cm.
  • There is a single manual door at this entrance.
  • The door opens away from you.
  • The width of the opening is 76cm.
  • The door has a high visual contrast.
  • There is a push pad or push button to exit at a height of 115cm.
  • There is step-free level access as you enter.
  • This entrance gives access to level -1. There is a narrow walkway (under 120cm but over 75cm wide) to reach this entrance from the car park.

Reception (Main Reception)

  • The reception is located immediately to the right as you enter through the main entrance.
  • The distance from the main entrance is 2m.
  • There is step-free level access to reception.
  • The height of the reception desk is 110cm.
  • There is a lowered section at the desk.
  • The height of the lowered section is 73cm.
  • There is not a hearing assistance system.
  • The height of the touchscreen display ranges from 108cm to 116cm from the floor.
  • The touchscreen is used for visitors to sign in and out. Staff are available to provide assistance if necessary. There is also a medium-height section of the Reception desk at a height of 90cm.
  • There may be background noise in this area.
  • The flooring is shiny.
  • Lighting levels vary due to the use of large glazed walls.
  • There is room for a wheelchair user to manoeuvre in the seating area (150cm x 150cm).
  • There is space for an assistance dog to rest in the seating area.
  • Seating available in this area includes: benches.
  • The seating is fixed.

Lift (Left of Building)

  • The lift surveyed is located diagonally to the left as you enter the building through the main entrance.
  • The distance from the main entrance is 8m.
  • The most accessible route to the lift has step-free level access.
  • Levels -1, 0, 1, 2 and 3 are accessed by this lift.
  • The lift door has a high visual contrast.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The external lift control buttons have a low visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 90cm.
  • The internal dimensions of the lift are 127cm (width) x 137cm (depth).
  • The internal lift control buttons have tactile markings, Braille markings and a medium visual contrast.
  • All of the internal lift controls are at a suitable height for a wheelchair user.
  • Internally the lift has: an audible announcer, a mirror to aid reversing and a visual floor indicator.
  • Lighting levels were low at the time of the survey.
  • There are other lifts available at this location which are of a similar size.
  • A key fob is required to operate the lift once inside. The key fob reader is placed at a height of 108cm.

Lift (Right of Building)

  • The lift surveyed is located diagonally to the right as you enter the building through the main entrance.
  • The distance from the main entrance is 8m.
  • The most accessible route to the lift has step-free level access.
  • Levels -1, 0, 1, 2 and 3 are accessed by this lift.
  • The lift door has a high visual contrast.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The external lift control buttons have a low visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 110cm.
  • The internal dimensions of the lift are 192cm (width) x 137cm (depth).
  • The internal lift control buttons have tactile markings, Braille markings and a medium visual contrast.
  • All of the internal lift controls are at a suitable height for a wheelchair user.
  • Internally the lift has: a visual floor indicator and a mirror to aid reversing.
  • Lighting levels were low at the time of the survey.
  • A key fob is required to operate the lift once inside. The key fob reader is placed at a height of 108cm.

Stairs (Left of Building)

  • The stairs surveyed are located to the left as you enter the building through the main entrance.
  • Levels -1, 0, 1, 2 and 3 can be accessed by these stairs.
  • There are 20+ steps between floors.
  • The steps are clearly marked and have handrails on both sides.
  • The handrails are easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails extend horizontally beyond the first and last step.
  • The height of the steps is between 15cm and 18cm.
  • The height of the highest step is 18cm.
  • The depth of the steps is not between 30cm and 45cm.
  • Lighting levels were even at the time of the survey.
  • There is a very similar staircase on the right hand side of the building; the only difference being that is does not access level -1.

Toilet with Adaptations (Level 0 - Right Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on Level 0, straight ahead and on your left as you enter the building through the main entrance.
    • The distance from the main entrance is 11m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 86cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 235cm (width) x 248cm (depth) and there is room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the right as you face the toilet.
    • The lateral transfer space is 155cm (from the side of the toilet pan).
    • There is a spatula flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a medium visual contrast.
    • The toilet seat is 48cm from the floor.
    • The toilet seat has a low visual contrast.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a medium visual contrast.
    • The toilet roll holder is 95cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 72cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which cannot be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 94cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 88cm from the floor.
    • There is a pull cord emergency alarm within 10cm from the floor.
    • There is a mirror.
    • There is a shelf, however there is an obstruction in front of it.
    • The shelf does not meet the AccessAble criteria for Stoma Friendly Toilets.
    • The cubicle has a nappy/incontinence items bin.
    • There are multiple coat hooks.
    • The coat hooks are 117cm and 173cm from the floor.
    • The walls and floor have a high visual contrast.
    • Lighting levels were even at the time of the survey.
    • There are identical toilets with adaptations to this in the same location on levels 1 and 2. These facilities all contain accessible showers. There is a flip down seat with a height of 47cm, a horizontal and vertical grab rail on the left, and dropdown rails on both sides of the seat. The shower is height-adjustable between 140cm and 170cm, and it is also detachable. There are lever mixer controls, and a shower curtain is available. There is an emergency pull cord alarm hanging within 10cm of the floor.

Toilet with Adaptations (Level 3 - Left Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on Level 3, to the left and left again as you exit the lift (left of building).
    • The distance from the lift (left of building) is 6m.
    • The most accessible route to the toilet has a lift and step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 86cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 246cm (width) x 247cm (depth) and there is room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the left as you face the toilet.
    • The lateral transfer space is 177cm (from the side of the toilet pan).
    • There is a spatula flush on the non-transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a medium visual contrast.
    • The toilet seat is 48cm from the floor.
    • The toilet seat has a low visual contrast.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a low visual contrast.
    • The toilet roll holder is 95cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 72cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which cannot be reached when seated on the toilet.
    • The soap dispenser has a medium visual contrast.
    • The soap dispenser is 91cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 106cm from the floor.
    • There is a pull cord emergency alarm within 10cm from the floor.
    • There is a mirror.
    • There is a shelf, however there is an obstruction in front of it.
    • The shelf does not meet the AccessAble criteria for Stoma Friendly Toilets.
    • The cubicle has a nappy/incontinence items bin.
    • There are multiple coat hooks.
    • The coat hooks are 117cm and 180cm from the floor.
    • The walls and floor have a high visual contrast.
    • Lighting levels were even at the time of the survey.
    • This facility contains an accessible shower. There is a flip down seat with a height of 47cm, a horizontal and vertical grab rail on the right, and dropdown rails on both sides of the seat. The shower is height-adjustable between 138cm and 168cm, and it is also detachable. There are lever mixer controls, and a shower curtain is available. There is an emergency pull cord alarm hanging within 10cm of the floor.

Standard Toilet Facilities

  • The male and female standard toilet facilities were surveyed.
  • The toilets are located straight ahead as you enter the building through the main entrance.
  • The distance from the main entrance is 11m.
  • The most accessible route has step-free level access.
  • There is step-free level access into the toilets.
  • There is pictorial signage on or near the door.
  • The door opens inwards and has a high visual contrast.
  • The width of the door opening is 76cm.
  • Internally the door has a high visual contrast.
  • There are ambulant toilet facilities available.
  • The ambulant cubicle has horizontal grab rails on both sides.
  • There is a wash basin, a wall mounted soap dispenser and a hand dryer available.
  • The wash basin has a push tap.
  • Lighting levels were even at the time of the survey.
  • There are very similar standard toilets on all levels (except level -1, which has no toilet facilities).