Skip to main content
The new name for DisabledGo

ECA North East Studio Building

The University of Edinburgh, Central Area, Lauriston Place, Edinburgh, EH3 3DF

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Overview

Getting Inside

  • There are slopes on approach to main entrance from the ECA Courtyard.
  • The main entrance is signed as the Welcome to Edinburgh College of Art.
    .
  • There is a level entrance between floor C of the ECA Main Building and floor J of ECA North East Studio.
    .
  • There is a staircase shared between ECA Main Building and the ECA North East Studio.
    There is a stepped entrance leading to rooms L.05 and L.06 on from floor E of the ECA Main Building.
    There is a ramped entrance between ECA Hunter Building floors N and P and the ECA North East Studio on floors J and L.

Getting Around

  • There is step free level access to the majority of the building.
    There is no step free access to floors G and H.
  • There is a steep slope to access L.27 and L.29 on floor L.
  • There are six clearly marked steps on floor J to access J.19A, J.19B, J.19C and the Male and Female Standard Toilets.
  • Floor surfaces along circulation routes are hard and smooth with some having a shiny finish.
  • There is limited seating in some circulation areas.
  • Wayfinding Signage is located throughout the building.

Emergency Egress for Building

  • General Building Information View
    • Please note the fire evacuation strategy from the upper floors of this building relies on the ability to self-transfer into an evacuation chair.

Toilet and Changing Facilities

  • Toilet Facilities View
    • There are 2 toilets with adaptations.
    • Toilets with adaptations are located on floors J and L.
    • The transfer space varies between left and right in the toilets with adaptations.
    • The male and female step-free toilet facilities are located I, J and L.
    • The shared step-free toilet facilities are located L.

Rooms and Services in the Building

Parking

  • Car Park View
    • The car park is located in front of the building.
    • The car park is open air/surface.
    • The car park surface consists of tarmac.
    • There are 2 designated Blue Badge parking bays available.
    • The Blue Badge bays are clearly marked.
    • The surveyed Blue Badge parking bay dimensions are 250cm (width) x 488cm (depth).
    • There is a marked zone to both sides and rear.
    • The width of the marked zone is 135cm.
    • The nearest designated bay is 10m from the main entrance.
    • The most accessible route from the Blue Badge parking has a slight ramp or slope.
    • There is a dropped kerb with tactile paving from the designated Blue Badge parking.
  • Charges and Restrictions View
    • This car park is for permit holders only.
    • Parking is free for all users.
    • Clearly presented parking signs are not available.
  • Drop-off Point View
    • There is not a designated drop-off point available.

Entrance (Main Entrance)

  • This entrance is located off the ECA Courtyard.
  • The entrance area is clearly signed.
  • There is a canopy or recess which provides weather protection at the entrance.
  • There is step-free access via ramp at the entrance.
  • The ramp has a slight gradient.
  • The ramp is between 75cm and 150cm wide with handrails on both sides.
  • There is a key fob/card reader at a height of 105cm.
  • There is a single automatic door at this entrance.
  • The door opens towards you.
  • The width of the opening is 85cm.
  • There is a small lip on the threshold of the opening.
  • The door has a high visual contrast.
  • There is a push pad or push button to exit at a height of 105cm.

Lift

  • The lift surveyed is located along the floor J Corridor.
  • The distance from the main entrance is 40m.
  • The most accessible route to the lift has step-free level access.
  • I Lower, I Upper, J Lower, J upper, K Lower, K Upper, L Lower, L Upper M are accessed by this lift.
  • The lift door has a high visual contrast.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The external lift control buttons have a low visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 80cm.
  • The internal dimensions of the lift are 106cm (width) x 140cm (depth).
  • The internal lift control buttons have tactile markings, Braille markings and a high visual contrast.
  • The majority of the internal controls are at a suitable height for a wheelchair user.
  • Internally the lift has: a separate door to exit, a hearing assistance alarm system, a visual floor indicator, an audible announcer and a list of floor services/facilities.
  • Lighting levels were even at the time of the survey.

Stairs

  • The stairs surveyed are located towards the left of the building.
  • G, H, I, J Lower, J Upper, K Lower, K Upper, L Lower, L Upper, and M can be accessed by these stairs.
  • There are 15 steps between floors.
  • The steps are clearly marked and have handrails on both sides.
  • The handrails are not easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails extend horizontally beyond the first and last step.
  • The height of the steps is between 15cm and 18cm.
  • The height of the highest step is 18cm.
  • The depth of the steps is not between 30cm and 45cm.
  • Lighting levels were even at the time of the survey.
  • Floors G and H only have handrails on either the right or the left going up.

Toilet with Adaptations (Floor J - Shared - Right Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located off the floor J corridor.
    • The distance from main entrance is 40m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial and written text signage on or near the door.
    • The door opens inwards and has a high visual contrast.
    • The width of the door opening is 86cm.
    • The door has a twist lock.
    • Internally the door has a low visual contrast.
    • There is not a grab rail on the internal door .
  • Dimensions and Features View
    • The dimensions of the cubicle are 162cm (width) x 255cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the right as you face the toilet, however it is obstructed.
    • The lateral transfer space is 90cm (from the side of the toilet pan).
    • There is a spatula flush on the right transfer side.
    • There is a horizontal grab rail on the left as you face the toilet.
    • The horizontal grab rail has a high visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 50cm from the floor.
    • The toilet seat has a low visual contrast.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a high visual contrast.
    • The toilet roll holder is 90cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 70cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 85cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 94cm from the floor.
    • There is a pull cord emergency alarm within 10cm from the floor.
    • There is a mirror.
    • There is no shelf.
    • The shelf does not meet the AccessAble criteria for Stoma Friendly Toilets.
    • The cubicle has a sanitary bin.
    • There is one coat hook.
    • The coat hook is 170cm from the floor.
    • The walls and floor have a high visual contrast.
    • Lighting levels were even at the time of the survey.