Access Guide
Overview
-
About
View
- The Alrick Building is a large building with 4 floors.
- There is 1 main lift and 1 main staircase.
- The floors are signed as G, 1, 2, 3 and 4.
- There is internal step-free access between the Alrick Building and Faraday Building via a sloped link bridge on floor 1.
There is also internal step-free access between the Alrick building and Fleeming Jenkin Building via a link bridge on floor 1.
-
Parking and Public Transport
View
- The venue does not have its own car park.
- View information on King's Buildings Campus Car Parks (opens new tab) .
- The nearest bus station is Edinburgh Bus Station.
- The nearest train station is Edinburgh Train Station.
- For the latest travel options and information you can plan your travel using Traveline.info (opens new tab).
Getting Inside
- The approach to the building is step-free via slight and steep slopes on the left and right.
- The building has one entrance. The entrance provides step-free access into the building via a slight slope. There are two sets of double manual doors at this entrance.
- The entrance is signed as School of Engineering Alrick Building.
Getting Around
- There is step-free level access throughout the building on all floors.
- Floor surfaces along all circulation routes are hard and smooth, with some having a shiny finish.
- There are no resting areas along the circulation routes or lobby areas.
- There is no wall mounted or overhead wayfinding signage in the building.
- There are manual doors in some corridors and lobby areas.
Emergency Egress for Building
-
General Building Information
View
- Please note the fire evacuation strategy from the upper floors of this building relies on the ability to self-transfer into an evacuation chair.
Toilet and Changing Facilities
-
Toilet Facilities
View
- There are 2 toilets with adaptations.
- Toilets with adaptations are located on the ground floor off the main lobby area, and on the third floor within the female standard toilets.
- All toilets with adaptations have a right hand transfer space.
- The male step-free toilet facilities are located on floors 1, 2 and 4.
- The female step-free toilet facilities are located on floors G and 3.
Rooms and Services in the Building
Parking (Max Born Crescent - Crew Buildings)
-
Car Park
View
- The car park is located on the left as you enter via Gate 1.
- The car park is open air/surface.
- The car park surface consists of tarmac, loose chippings and unsurfaced areas.
-
Charges and Restrictions
View
- This car park is for permit holders only.
- Parking is not free for all users.
- Parking is free for Blue Badge holders.
- Clearly presented parking signs are not available.
- View information on parking policies/charges (opens new tab).
- Staff and students Blue Badge holders who wish to park within the City, King's Buildings or Easter Bush Campus car parks should apply for a Disabled All Areas Permit.
-
Drop-off Point
View
- There is not a designated drop-off point available.
Entrance
- This entrance is located at the front of the building.
- The approach to the entrance has uneven surfaces and bollards.
- The entrance area is clearly signed.
- There is not a canopy or recess which provides weather protection at the entrance.
- There is step-free access via ramp at the entrance.
- The ramp has a steep gradient.
- The ramp is over 150cm wide with no handrails.
- The bollards are 165cm apart.
- There are double manual doors at this entrance, however one door is locked.
- The doors opens away from you.
- The width of the opening is 85cm.
- There is a small lip on the threshold of the opening.
- The doors have a low visual contrast.
- There is a second set of double manual doors .
- The second set of doors open away from you.
- The width of the opening is 170cm.
- There is a small lip on the threshold of the opening.
- The second set of doors have a low visual contrast.
- There is step-free level access as you enter.
Stairs
- The stairs surveyed are located on the right side of the building.
- There are double manual doors to access the stairwell.
- The ground, first, second, third and fourth floors can be accessed by these stairs.
- There are 20+ steps between floors.
- The steps have low visual contrast markings and have a handrail on the left going up.
- The handrail is easy to grip.
- The handrail covers the flight of stairs throughout its length.
- The handrail does not extend horizontally beyond the first and last step.
- The height of the steps is between 15cm and 18cm.
- The height of the highest step is 17cm.
- The depth of the steps is not between 30cm and 45cm.
- Lighting levels vary due to the size of the space.
Lift
- The lift surveyed is located on the right side of the building.
- The distance from the entrance is 8m.
- The most accessible route to the lift has step-free level access and manual doors.
- The ground, first, second, third and fourth floors are accessed by this lift.
- The lift door has a high visual contrast.
- The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
- The external lift control buttons have tactile markings, Braille markings and a high visual contrast.
- All of the external lift controls are at a suitable height for a wheelchair user.
- The lift door opening width is 79cm.
- The internal dimensions of the lift are 103cm (width) x 137cm (depth).
- The internal lift control buttons have tactile markings, Braille markings and a high visual contrast.
- Some of the internal lift controls are at a suitable height for a wheelchair user.
- Internally the lift has: a mirror to aid reversing, a hearing assistance alarm system, a visual floor indicator and an audible announcer.
- Lighting levels were low at the time of the survey.
Toilet with Adaptations (Ground Floor - Right Hand Transfer)
-
Location and Access
View
- The toilet surveyed is located on the ground floor.
- The distance from the entrance is 11m.
- The most accessible route to the toilet has step-free level access.
- There is step-free level access into the facility.
- There is pictorial and written text signage on or near the door.
- The door opens outwards and has a high visual contrast.
- The width of the door opening is 89cm.
- The door has a sliding bolt lock.
- Internally the door has a high visual contrast.
- There is not a grab rail on the internal door .
-
Dimensions and Features
View
- The dimensions of the cubicle are 194cm (width) x 174cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
- There is a lateral transfer space to the right as you face the toilet, however it is obstructed.
- The lateral transfer space is 126cm (from the side of the toilet pan).
- There is a lever flush on the transfer side.
- There is a horizontal grab rail on the non-transfer side.
- The horizontal grab rail has a high visual contrast.
- There are vertical grab rails on both sides of the toilet.
- The vertical grab rails have a high visual contrast.
- There is a dropdown rail on the transfer side.
- The dropdown rail has a high visual contrast.
- The toilet seat is 48cm from the floor.
- The toilet seat has a high visual contrast.
- There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
- The toilet roll holder has a low visual contrast.
- The toilet roll holder is 88cm from the floor.
- The wash basin and taps cannot be reached when seated on the toilet.
- The wash basin is 74cm from the floor.
- The wash basin has a lever mixer tap.
- The vertical grab rail is on the right as you face the wash basin.
- The wash basin grab rail has a high visual contrast.
- There is a wall mounted soap dispenser which can be reached when seated on the toilet.
- The soap dispenser has a low visual contrast.
- The soap dispenser is 88cm from the floor.
- There is a wall mounted towel dispenser which cannot be reached when seated on the toilet.
- The towel dispenser has a low visual contrast.
- The towel dispenser is 107cm from the floor.
- There is not a hand dryer.
- There is a pull cord emergency alarm within 10cm from the floor.
- There is no mirror.
- There is no shelf.
- The cubicle has a waste bin and a sanitary bin.
- There are no coat hooks.
- The walls and floor have a high visual contrast.
- Lighting levels vary due to the use of large glazed walls.