Skip to main content
The new name for DisabledGo

Hudson Beare Building

The University of Edinburgh, King's Buildings, Colin Maclaurin Road, Edinburgh, EH9 3DW

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Overview

Getting Inside

  • The approach to the building via the Faraday Building main entrance is step-free via a slight ramp from the Colin Maclaurin Road Car Park.
  • The Hudson Beare Building has two entrances and a link entrance from the Sanderson Building.
    The Hudson Beare Building main entrance provides step-free level access (accessible entrance).
  • The entrances are not individually signed.
    Each entrance is signed with the building name.
  • The main entrance gives direct access to the Ground Floor, with step-free level access to the majority of the building.
    There is stepped access only to the Basement from the Ground Floor.
  • The rear entrance has stepped access with manual doors.
    The link entrance from the Sanderson Building is step-free with a slight ramp and manual doors.
  • There is additional access to the main entrance from the Faraday Building secondary entrance to the Faraday entrance lobby, which is step-free with a slight ramp and manual door.

Getting Around

  • There is step-free access throughout the Ground Floor of the building.
  • There is stepped access only to the Basement from the Ground Floor.
    There is internal access to the Basement via a staircase at the rear of the building and café.
  • Floor surfaces along all circulation routes are hard and smooth, with some having a shiny and/or patterned finish.
  • There are no resting areas in circulation or lobby areas.
    There is seating in the café with a mixture of seating.
  • There are no wayfinding signage or floor plans to assist people in finding their way around.
  • There are manual doors in some corridors to access the toilet facilities and lecture theatre.

Emergency Egress for Building

  • General Building Information View
    • Please note the fire evacuation strategy from the upper floors of this building relies on the ability to self-transfer into an evacuation chair.

Toilet and Changing Facilities

  • Toilet Facilities View
    • There is 1 toilet with adaptations.
    • The toilet with adaptations is located at the rear of the café on the Ground Floor.
    • The toilet with adaptations has a right hand transfer space.
    • Ambulant toilet facilities are located in the male and female standard toilet facilities .
    • The male and female toilet facilities are located at the rear of the café on the Ground Floor.
  • Washroom and Shower Facilities View
    • There is a heavy single manual door 75cm+ wide to access the toilet facilities.
      It has a high colour contrast.

Rooms and Services in the Building

Entrance (Faraday Main Entrance)

  • This entrance is located off the Colin Maclaurin Road car park.
  • The entrance area is clearly signed.
  • There is not a canopy or recess which provides weather protection at the entrance.
  • There is step-free access via ramp at the entrance.
  • The ramp has a slight gradient.
  • The ramp is between 75cm and 150cm wide with handrails on both sides.
  • The ramp bypasses the steps.
  • There are 4 steps with handrails on both sides.
  • The handrails are easy to grip.
  • The handrail covers the flight of stairs throughout its length.
  • The handrails extend horizontally beyond the first and last step.
  • The steps are unmarked.
  • The steps have tactile markings at the top and bottom.
  • The height of the step is between 15cm and 18cm.
  • The height of the highest step is 15cm.
  • The depth of the steps is not between 30cm and 45cm.
  • There is a key pad at a height of 94cm.
  • The key pad is for out of hours working only.
  • There is a single automatic door at this entrance.
  • The door opens away from you.
  • The width of the opening is 83cm.
  • There is a small lip on the threshold of the opening.
  • The door has a high visual contrast.
  • There is a push pad or push button to exit at a height of 89cm.
  • This entrance provides accessible access to the Faraday Building, the Fleeming Jenkin Building (via the Faraday Building) and the Hudson Beare Building.

Entrance (Hudson Beare Main Entrance)

  • This entrance is located to the left as you enter via the Faraday main entrance.
  • The entrance area is clearly signed.
  • There is step-free level access at the entrance.
  • There is a single automatic door at this entrance.
  • The door opens towards you.
  • The width of the opening is 86cm.
  • The door has a high visual contrast.
  • The entrance has an unlocked. manual opening extension leaf.
    The total clear width when this and the door are open is 135cm.

Stairs

  • The stairs surveyed are located to the rear of the building, at the back of the café .
  • The Basement and Ground floor can be accessed by these stairs.
  • There are 17 steps between floors.
  • The steps are unmarked and have handrails on both sides.
  • The handrails are not easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails do not extend horizontally beyond the first and last step.
  • The height of the step is between 15cm and 18cm.
  • The height of the highest step is 17cm.
  • The depth of the steps is not between 30cm and 45cm.
  • The stairs give access to the Basement and Engineering Maker Space.
    Access is restricted outside of the Maker Space opening times.

Toilet with Adaptations (Ground Floor - Eng Inn Café - Right Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located at the rear of the building, to the rear of the café.
    • The distance from the Hudson Beare main entrance is 35m.
    • The most accessible route to the toilet has manual doors, step-free level access and automatic doors.
    • There is step-free level access into the facility.
    • There is a heavy manual door 75cm+ wide that opens away from you to enter the toilet facilities area.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 92cm.
    • The door has a locking handle.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 169cm (width) x 225cm (depth) and there is room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the right as you face the toilet, however it is obstructed.
    • The lateral transfer space is 101cm (from the side of the toilet pan).
    • There is a spatula flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a high visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a high visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a high visual contrast.
    • The toilet seat is 48cm from the floor.
    • The toilet seat has a high visual contrast.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a low colour contrast.
    • The toilet roll holder is 97cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 72cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a high visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 95cm from the floor.
    • There is a wall mounted towel dispenser which can be reached when seated on the toilet.
    • The towel dispenser has a low visual contrast.
    • The towel dispenser is 95cm from the floor.
    • There is a wall mounted hand dryer.
    • The hand dryer has a high visual contrast.
    • The hand dryer is 77cm from the floor.
    • There is a pull cord emergency alarm within 10cm from the floor.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a waste bin and a sanitary bin.
    • There are multiple coat hooks.
    • The coat hooks are 100cm and 140cm from the floor.
    • The walls and floor have a high visual contrast.