Skip to main content
The new name for DisabledGo

Sport and Active Health

University of Dundee, Old Hawkhill, Dundee, DD1 5AA

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Summary

  • Building View
  • Location of Toilet/Changing Facilities View
    • Accessible toilet facilities are located on the lower ground floor in the rear corridor opposite Sports Hall 2, and on the second floor next to Studio 2.
    • Accessible toilet facilities with an accessible shower are located on the first floor next to Studio 1.
    • Female standard toilet facilities are located in the front corridor changing area on the upper ground floor, off the rear corridor on the lower ground floor opposite Sports Hall 2, and on the second floor next to Studio 2.
    • Male standard toilet facilities are located in the front corridor changing area on the upper ground floor, off the rear corridor on the lower ground floor opposite Sports Hall 2, and on the second floor next to Studio 2.
    • Accessible changing facilities are located on the upper ground floor, to the left in the front corridor.
    • Standard changing facilities are located off the upper ground floor front corridor, and off the lower ground floor left corridor.
    • Accessible shower facilities are located within the accessible changing room on the upper ground floor, and in the first floor accessible toilet.
    • Standard shower facilities are located on the upper ground floor in the front corridor changing areas, and on the lower ground floor in the rear changing areas.

Getting Here (City Campus)

  • By Road View
    • The postcode for the Tower Building, the main administration building and campus entrance at the City Campus, is DD1 4HN. The campus is located between Perth Road and Hawkhill, to the west of Dundee city centre. Dundee can be accessed via the A90 from the North and West or the A92 from the east and south.
    • Car parking on the city campus is for staff permit holders only Monday to Friday 08:00 to 17:30. Staff, students, or visitors with a local authority issued Blue Badge may park for free, without a permit, in designated accessible parking bays only. Official visitors should contact the department they are visiting to arrange a temporary permit. Non permit holders may park out with the standard parking times by paying an appropriate fee via the RingGo app. Fees for non-permit holders are applicable Monday to Friday from 17:30 to 00:00 and Saturday and Sunday from 08:00 to 00:00.
  • By Bus View
    • There is a bus stop within 150 metres of the campus.
    • The nearest bus stops on the south side of the campus are located on Perth Road. Bus routes 5, 5A, 16, 16B, 17, 36C, 39, 73, 73A and 204 all serve these stops. The nearest bus stops on the north side of the campus are located on Hawkhill. Bus routes 6, 22, 51 and 922 serve these stops.
    • For more information on Stagecoach bus services please click here (opens new tab).
  • By Train View
  • Useful Links View

Useful Information

Building Parking (Kincardine Street)

  • The building does have its own dedicated parking.
  • Building Car Park View
    • The car park can be used by staff, students, visitors and Blue Badge holders.
    • There are no parking charges that apply on the day.
    • The car park is located to the rear right of the building.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • Designated Blue Badge parking bays are available.
    • There is/are 4 designated parking bay(s) within the car park.
    • The Blue Badge bay(s) is/are clearly marked and signposted.
    • The dimensions of the designated parking bay(s) are 270cm x 480cm.
    • The Blue Badge parking bays have a marked zone to both sides but not at the rear.
    • The marked zone is 108cm wide.
    • The dimensions of the designated bays do not vary in size.
    • Parking spaces for Blue Badge holders do not need to be booked in advance.
    • The nearest designated bay is 110m (120yd 11in) from the main entrance.
    • The route from the car park to the building is accessible to a wheelchair user with assistance.
    • Assistance may be required because there is / are dropped kerbs.
    • The dropped kerb between the car park and the building does not have tactile paving.
    • The car park surface is tarmac.
  • Site/Campus Car Parks View
    • There is a site/campus car park for staff and students within approximately 200m.
    • The name of the car park is Old Hawkhill Car Park.
    • The car park is located Old Hawkhill to the left of the building.
  • Public Car Parks View
    • There is a car park for public use within 200m (approx).
    • The name of the car park is Hunter Street Pay and Display.
    • The car park is located on Hunter Street.
  • On Street Parking View
    • Clearly signed and/or standard marked parking bays are not available.
  • Drop Off Point View
    • There is not a designated drop off point.

Site/Campus Car Park (Old Hawkhill Car Park)

  • Car Park View
    • The car park is located on Old Hawkhill, Dundee DD1 5AA.
    • The nearest building(s) to this car park is/are the Sport and Active Health, Sports Biomedicine, and the Life Sciences buildings.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is tarmac.
    • Designated Blue Badge parking bays are available.
    • The Blue Badge bay(s) is/are clearly marked.
    • There is/are 3 designated Blue Badge parking bay(s) within this car park.
    • The dimensions of the designated parking bay(s) are 245cm x 480cm.
    • The Blue Badge parking bays have a marked zone to both sides but not at the rear.
    • The marked zone is 110cm wide.
    • The dimensions of the designated bays do not vary in size.
  • Charges and Restrictions View
    • This car park can be used by visitors, Blue Badge holders and permit holders.
    • Parking charges apply to visitors only.
    • Signs are provided to give information on parking charges/restrictions.
    • Signs are clearly presented.
    • Payment can be made by phone.
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is step free access from this car park.
    • Buildings are not clearly signposted from this car park.
    • There is not a campus map available within the car park.
    • The nearest designated bay is 35m (38yd 10in) from the School of Life Sciences main entrance.

Outside Access (Main Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to the reception foyer on the ground floor.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'ise institute of sports and exercise'.
    • There is ramped/sloped or stepped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) automatically (towards you).
    • There is a push pad/button to enter and exit the main automatic doors.
    • The entry push pad or push button is 93cm from floor level.
    • The exit push pad or push button is 90cm from floor level.
    • The door(s) is/are single width with a locked extension leaf.
    • The width of the door opening is 90cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is also a revolving door next to this one.
  • Ramp/Slope View
    • The ramp/slope is located to the left as you face the entrance.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is not a/are not handrail(s) at the ramp.
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • The step(s) is/are located to the right as you face the entrance.
    • There is/are 3 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 17cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).

Reception (Main Reception and Entrance Lobby)

  • Reception View
    • The reception point is located to the left as you enter.
    • The reception point is approximately 18m (19yd 2ft) from the main entrance.
    • The reception area/desk is clearly visible from the entrance.
    • There is step-free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is not placed in front of a background which is patterned.
    • The lighting levels at the reception point are good.
    • The height of the reception counter is 119cm.
    • There is sufficient space to write or sign documents on the counter.
    • There is a lowered section of the counter.
    • The height of the lowered section at the counter is 80cm.
    • There is sufficient space to write or sign documents on the lowered section of the counter.
    • There is a clear knee recess beneath the counter.
    • The counter is staffed.
    • Clipboards can be provided to anyone who is unable to use the desk.
    • There is a hearing assistance system at the reception point.
    • The type of system is a fixed loop.
    • The hearing assistance system is signed.
    • Staff are not trained to use the hearing system.
    • The hearing assistance system was tested by an AccessAble surveyor.
    • The hearing assistance system was tested on 11/03/2024.
    • The hearing loop was working at the time of testing.
    • There is no wayfinding signage available at/close to the reception.
    • The type of flooring in the reception area is carpet.
  • Reception Waiting Area View
    • There is a waiting area close to the reception point.
    • Access to the waiting area is unobstructed.
    • There is bench seating and single seats with armrests.
    • There is sufficient space for a wheelchair user to use the waiting area.

Getting Around

  • Access View
    • There is step-free access throughout the majority of the building, via lift.
    • There is sloped/ramped access to the upper ground floor (changing rooms, science@ise, sports union), and lower ground floor (gym, sports halls and changing rooms).
  • Circulation View
    • There are doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is carpet.
    • Handrails with a rounded or oval profile are not provided in corridors/walkways.
    • There is high visual contrast between the walls and floor in the majority of corridors/walkways.
    • There are seats without armrests at regular intervals.
    • The lighting levels are good.
  • Signage View
    • Wayfinding signage is not provided.
    • Dementia friendly signage is not provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does play background music in communal areas.
    • Music is played in the gym.
    • There is not a hearing assistance system in the communal areas of the building.

Ramp(s) / Slope(s) and Step(s) (Entrance Lobby - Rear)

  • Ramp / Slope View
    • There is a ramp/slope located leading down to the rear right of the entrance lobby.
    • The ramp/slope is used to access the lower ground floor.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on both sides.
    • The width of the ramp/slope is 118cm (3ft 10in).
    • The lighting levels at the ramp/slope are good.
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • There is a/are step(s) located leading down to the right of the ramp.
    • The step(s) is/are used to access the lower ground floor.
    • There is/are 5 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 16cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.

Ramp(s) / Slope(s) and Step(s) (Entrance Lobby - Left)

  • Ramp / Slope View
    • There is a ramp/slope located to the rear left of the lobby.
    • The ramp/slope is used to access the upper ground floor.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on both sides.
    • The width of the ramp/slope is 118cm (3ft 10in).
    • The lighting levels at the ramp/slope are good.
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • There is a/are step(s) located to the left behind reception.
    • The step(s) is/are used to access the upper ground floor and stairs.
    • There is/are 6 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 14cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).
    • The lighting levels at the step(s) are good.

Ramp(s) or Slope(s) (Front Corridor)

  • Ramped/Sloped Level Change 1 View
    • There is a ramp/slope located on the upper ground floor.
    • The ramp/slope is used to access the front corridor.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on both sides.
    • The lighting levels at the ramp/slope are good.

Step(s) (Left Corridor)

  • Stepped Level Change 1 View
    • There is a/are step(s) located on the upper ground floor, leading down to the right from the front corridor.
    • The step(s) is/are used to access the left corridor.
    • There is/are 4 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 16cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • The depth of the steps are 26cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.
  • Stepped Level Change 2 View
    • There is a/are step(s) located leading up to the left from the left corridor.
    • The step(s) is/are used to access hall 1 east.
    • There is/are 6 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 14cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • The depth of the steps are 28cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.
    • The front corridor slope can be used to bypass these steps.
  • Stepped Level Change 3 View
    • There is a/are step(s) located in the left corridor, leading down beyond the double doors.
    • The step(s) is/are used to access the left corridor changing rooms.
    • There is/are 6 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 17cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • The depth of the steps are 29cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.
    • The rear lobby ramp can be used to bypass these steps.

Other Floors

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located behind reception.
    • The stairs are approximately 10m from the main entrance.
    • The stairs are clearly visible from the entrance.
    • The floors which are accessible by the stairs are G, 1, 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The depth of the steps is 27cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are provided on landings.
    • The lighting levels at the steps are good.

Lift

  • The lift is located round to the right as you enter.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 20m (21yd 2ft) from the main entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are G, M, 1, 2.
  • The weight limit for the lift is 630.
  • There are manual, heavy, single doors to access the lift lobby on the mezzanine floor.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The visual contrast between the external lift controls and the control plate is low.
  • The visual contrast between the external lift control plate and the wall is high.
  • The clear door width is 90cm (2ft 11in).
  • The dimensions of the lift are 95cm x 133cm (3ft 1in x 4ft 4in).
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • There is a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are moderate to good.
  • The audible announcer does not announce the Mezzanine level.

Reception (Gym)

  • Reception View
    • The reception point is located to the left as you enter the gym.
    • The reception point is approximately 5m (5yd 1ft) from the gym entrance.
    • The reception area/desk is clearly visible from the entrance.
    • There is step-free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is not placed in front of a background which is patterned.
    • The lighting levels at the reception point are moderate to good.
    • The height of the reception counter is 100cm.
    • There is sufficient space to write or sign documents on the counter.
    • There is not a lowered section of the counter.
    • There is not a clear knee recess beneath the counter.
    • The counter is not staffed.
    • There is not a bell to attract attention.
    • There is not a hearing assistance system at the reception point.
    • There is no wayfinding signage available at/close to the reception.
    • The type of flooring in the reception area is wood and laminate.
  • Reception Waiting Area View
    • There is not a waiting area close to the reception point.

Gym

  • There are manual, heavy, double doors to access the gym.
  • The door(s) open(s) away from you.
  • The width of the door opening is 162cm.
  • The entrance area/door is not clearly signed.
  • The door(s) does/do contrast visually with its immediate surroundings.
  • The gym is staffed when open.
  • There is not an emergency alarm in the gym.
  • Staff receive training in assisting disabled people.
  • There is not clear manoeuvring space between equipment.
  • There is level access to all of the equipment.
  • Equipment suitable for mobility or sensory impaired users includes; free weights, cable resistance machines and upper body machines where fixed seats can be removed.
  • In this area there are bench seats available.
  • Background music is played.
  • The flooring in the gym consists of wood and laminate.
  • There is not a hearing assistance system.
  • The gym is split over two floors with access via internal stairs, or the nearby lift to the mezzanine level.
    There are also weight training areas opposite the gym entrance, and to the left from the lift on the first floor.

Other Floors (Gym)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located to the left as you enter the gym.
    • The stairs are approximately 2m from the gym entrance.
    • The stairs are clearly visible from the entrance.
    • The floors which are accessible by the stairs are G, M.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The depth of the steps is 29cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are moderate to good.

Sports Halls

  • There are two large multi-purpose sport halls.
  • Hall 1 is to the left on the upper ground floor level, and can be split into two - Hall 1 East and Hall 1 West. Hall 1 also has a mezzanine viewing gallery that can be accessed by steps only.
  • Hall 2 is to the rear on the lower ground floor, and can be split into two - Hall 2 East and Hall 2 West.

Other Floors (Sports Hall 1 - Viewing Galleries)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located off the front corridor on the upper ground floor.
    • The stairs are approximately 75m from the main entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, single doors to enter and exit the stairwell on the first floor.
    • The floors which are accessible by the stairs are G, 1.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The depth of the steps is 28cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on the right going up.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are moderate to good.
  • Other Information View
    • The area(s) on the floors which are not accessible is/are Sports Hall 1 (East and West) viewing galleries.

Other Rooms

  • There are 3 multi-function studios and 3 squash courts.
  • Studio 1 is located on the first floor, to the right out of the lift.
  • Studio 2 is located on the second floor, to the right out of the lift.
  • Studios 1 and 2 are used for fitness and active living classes.
  • Studio 3 is located on the upper ground floor level to the far left of the building. This is a Spin Studio. Spin classes are group cycling exercise classes focused on resistance-based intervals, heart rate training, and sometimes getting a full-body workout. There are no hand bikes available.
  • The 3 Squash Courts are located on the second floor to the left as you exit the lift. The glass doors to the squash courts are 73cm wide.

Changing Area (Front Corridor - Male G.08 and Female G.35)

  • Changing Area View
    • There is a/are changing area(s) available.
    • The changing area that was surveyed is located to the left as you enter, in the front corridor.
    • The changing area is approximately 60m from the main entrance.
    • The changing area is approximately 50m from reception.
    • The changing area is approximately 15m from the Sports Hall 1.
    • There is ramped/sloped or stepped access to the changing area.
    • The facilities available within the changing area include; standard changing rooms/cubicles, standard showers and standard toilets.
    • This is a male changing area.
    • Similar female changing area(s) are available.
    • The door(s) open(s) away from you (push).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 82cm.
    • The type of flooring in the changing area is vinyl.
    • There is not a flashing fire alarm beacon within the changing area.
    • There are changing benches or seats within the changing area.
    • There are lockers within the changing area.
    • There is a/are locker(s) within reach for a wheelchair user.
    • There is not a water dispenser available.
    • The lighting levels in the changing area are good.
  • Shower Facilities View
    • Shower facilities are available.
    • There is stepped access to the shower facilities.
    • There is a shallow 13cm clearly marked step into the shower area.
    • The shower head height(s) is/are fixed.
    • The shower control type(s) is/are lever.
    • There is no seat for the shower(s).
    • There is not a/are not wall-mounted grab rail(s) available for the shower(s).
  • Toilet Facilities View
    • Toilet facilities are available.
    • There is step-free access to the toilet(s).
    • An ambulant toilet with wall-mounted grab rails is not available.
    • The wash basin(s) tap type is twist/turn.
    • The lighting levels in the toilet(s) are good.
  • Baby Changing Facilities View
    • Baby changing facilities are not available.

Changing Area (Left Corridor - Male G.39 and Female G.41)

  • Changing Area View
    • There is a/are changing area(s) available.
    • The changing area that was surveyed is located to the rear left of the building, on the lower ground floor.
    • The changing area is approximately 65m from the main entrance.
    • The changing area is approximately 55m from reception.
    • The changing area is approximately 25m from the Sports Hall 2.
    • There is step-free access to the changing area.
    • The facilities available within the changing area include; standard changing rooms/cubicles and standard showers.
    • This is a male changing area.
    • Similar female changing area(s) are available.
    • The door(s) open(s) away from you (push).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 86cm.
    • The type of flooring in the changing area is vinyl.
    • There is not a flashing fire alarm beacon within the changing area.
    • There are changing benches or seats within the changing area.
    • There are lockers within the changing area.
    • There is a/are locker(s) within reach for a wheelchair user.
    • There is not a water dispenser available.
    • The lighting levels in the changing area are moderate to good.
  • Shower Facilities View
    • Shower facilities are available.
    • There is step-free access to the shower facilities.
    • The shower head height(s) is/are fixed.
    • The shower control type(s) is/are twist/turn.
    • There is no seat for the shower(s).
    • There is not a/are not wall-mounted grab rail(s) available for the shower(s).
  • Toilet Facilities View
    • Toilet facilities are not available.

Accessible Changing Room (Front Corridor - Right Hand Transfer)

  • Location and Access View
    • This accessible changing room is located to the left of the front corridor on the upper ground floor, before the double doors.
    • This accessible changing room is approximately 65m from the main entrance.
    • The accessible changing room is approximately 10m from the Sports Hall 1.
    • There is ramped/sloped access into the accessible changing room.
    • A key is not required for the accessible changing room.
    • There is pictorial signage on or near the accessible changing room door.
    • The visual contrast between the external door and wall is high.
    • The door opens inwards.
    • The door is heavy.
    • The door is locked by a lever twist.
    • The width of the accessible changing room opening is 86cm.
    • The contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
  • Changing Facilities View
    • The dimensions of the accessible changing room are 255cm x 340cm.
    • The fixtures/facilities available in the accessible changing room include; a chair/stool, handrails, a dropdown rail, a toilet, a wash basin and a wheel in shower.
    • This is a shared changing room.
    • The type of flooring in the changing room is vinyl.
    • There is not a red flashing fire alarm beacon within the accessible changing room.
    • There is seating available within the changing room.
    • The seating within the changing room includes: a flip down/tip up seat and a chair without armrests.
    • There are no lockers within the changing room.
    • There is not a water dispenser available.
    • There is a/are coat hook(s).
    • The height of the coat hook is 130cm from the floor.
    • The lighting levels in the changing room are moderate to good.
  • Toilet Features View
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are moderate to good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 185cm (6ft 1in).
    • There is a flush on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) and wall is high.
    • The visual contrast between the walls and floor is medium.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are available.
    • There is a/are general waste (with no lid) disposal units.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is a colostomy bag shelf next to the toilet.
    • The colostomy bag shelf is at a height of 94cm.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 48cm (1ft 7in).
    • The toilet seat visual contrast is high.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 88cm (2ft 11in).
    • The visual contrast between the toilet roll holder and the wall is medium.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 71cm (2ft 4in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is high.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 88cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 78cm (2ft 7in).
    • The visual contrast between the hand dryer and the wall is high.
  • Accessible Shower View
    • The shower does have an unobstructed minimum 150cm x 150cm turning space.
    • There is a shower unit with a detachable shower head.
    • The shower head is height adjustable.
    • The adjustable shower head can be placed between 105cm and 185cm when mounted.
    • There is a flip-down/tip-up seat for the shower.
    • The seat/chair is not height adjustable.
    • The height of the flip-down/tip-up or fixed seat is 45cm (1ft 6in).
    • Horizontal and/or dropdown rails are available on both sides of the shower seat.
    • The visual contrast between the shower rails and wall is high.
    • There is a vertical grab rail for the shower.
    • The visual contrast between the vertical grab rail(s) for the shower and wall is high.
    • There is an emergency alarm for the shower.
  • Baby Changing Facilities View
    • There is a 51cm high flip down seat with a drop down rail on the non-transfer side.
      There is a 48cm high portable seat/shower chair available.

Toilet with Adaptations (Rear Corridor G.42A - Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located to the left from the rear ramp on the lower ground floor.
    • This accessible toilet is approximately 45m (49yd 8in) from the main entrance.
    • There is ramped/sloped access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens inwards and outwards.
    • The door is light.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 86cm (2ft 10in).
    • The contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 150cm x 258cm (4ft 11in x 8ft 6in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 73cm (2ft 5in).
    • The transfer space is obstructed by a female sanitary bin and a waste disposal bin.
    • There is a flush on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is low.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the walls and floor is high.
    • There is not an emergency alarm.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with lid) disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf does not have the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 88cm.
    • The shelf is not located where it is reachable.
    • The toilet has a cistern.
    • There is a lid attached to the toilet seat.
    • The height of the toilet seat above floor level is 44cm (1ft 5in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 101cm (3ft 4in).
    • The contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) cannot be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 73cm (2ft 5in).
    • There is a vertical wall-mounted grab rail on the right hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 95cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer requires hands to be inserted into the top.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 86cm (2ft 10in).
    • The contrast between the hand dryer and the wall is high.

Toilet with Adaptations (First Floor 1.52 with shower - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located on the first floor, to the right from the lift.
    • This accessible toilet is approximately 9m (9yd 2ft) from the lift.
    • There is step-free access into the accessible toilet, via lift.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens by sliding (Bi-Fold).
    • The door is heavy.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 81cm (2ft 8in).
    • The contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
  • Toilet Features View
    • The dimensions of the accessible toilet are 151cm x 274cm (4ft 11in x 8ft 12in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 80cm (2ft 7in).
    • The transfer space is obstructed by a waste disposal bin.
    • There is a flush, however it is not on the transfer side.
    • There is not a spatula type lever flush.
    • There is a push button flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is medium.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on the right.
    • There is not a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is medium.
    • The contrast between the walls and floor is medium.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and pedal bin disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is not a shelf within the accessible toilet.
    • The toilet has a wall which acts as a backrest.
    • The height of the toilet seat above floor level is 44cm (1ft 5in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder cannot be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 91cm (2ft 12in).
    • The contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 77cm (2ft 6in).
    • There is a vertical wall-mounted grab rail on the left hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is medium.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 94cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 101cm (3ft 4in).
    • The contrast between the hand dryer and the wall is low.
  • Accessible Shower View
    • The shower does not have an unobstructed minimum 150cm x 150cm turning space.
    • There is a shower unit with a detachable shower head.
    • The shower head is height adjustable.
    • The adjustable shower head cannot be placed between 105cm and 185cm when mounted.
    • There is a flip-down/tip-up seat for the shower.
    • The seat/chair is not height adjustable.
    • The height of the flip-down/tip-up or fixed seat is 47cm (1ft 7in).
    • Horizontal and/or dropdown rails are available on both sides of the shower seat.
    • The visual contrast between the shower rails and wall is medium.
    • There is not a vertical grab rail for the shower.
    • There is not an emergency alarm for the shower.

Toilet with Adaptations (Second Floor 2.51 - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located on the second floor, to the right from the lift.
    • This accessible toilet is approximately 9m (9yd 2ft) from the lift.
    • There is step-free access into the accessible toilet, via lift.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens by sliding (Bi-Fold).
    • The door is heavy.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 78cm (2ft 7in).
    • The contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 150cm x 174cm (4ft 11in x 5ft 9in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 82cm (2ft 8in).
    • The transfer space is obstructed by a waste disposal bin.
    • There is a flush, however it is not on the transfer side.
    • There is not a spatula type lever flush.
    • There is a push button flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is medium.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is medium.
    • The contrast between the walls and floor is medium.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and pedal bin disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is not a shelf within the accessible toilet.
    • The toilet has a wall which acts as a backrest.
    • There is a lid attached to the toilet seat.
    • The height of the toilet seat above floor level is 44cm (1ft 5in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 88cm (2ft 11in).
    • The contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 77cm (2ft 6in).
    • There are no vertical wall-mounted grab rails at the wash basin.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 91cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer requires hands to be inserted into the top.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 86cm (2ft 10in).
    • The contrast between the hand dryer and the wall is high.

Standard Toilet(s) (Front Corridor - Changing Areas G.08 and G.35)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located within the standard changing rooms.
    • There is ramped/sloped access into the toilet(s).
    • The standard toilet(s) is/are approximately 50m from the main entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 78cm.
    • The wash basin(s) tap type is twist/turn.
    • Lighting levels are good.

Standard Toilet(s) (Rear Corridor - Female G.43, Male G.42)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located to the left from the rear foyer ramp to the lower ground floor.
    • There is ramped/sloped access into the toilet(s).
    • The standard toilet(s) is/are approximately 45m from the main entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 81cm.
    • The wash basin(s) tap type is twist/turn.
    • Lighting levels are moderate to good.

Standard Toilet(s) (Second Floor - Female 2.52, Male 2.50)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located on the second floor, to the right from the lift.
    • The standard toilet(s) is/are approximately 10m from the lift.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 80cm.
    • The wash basin(s) tap type is lever mixer.
    • Lighting levels are good.