Skip to main content
The new name for DisabledGo

Access Guide

Show Easy Read

Accommodation Summary

  • Parking and Transport View
    • The accommodation has its own parking facilities.
    • No secure parking is available.
    • There is not a designated drop off point.
    • There is a university bus service stop within approximately 200 metres of the residence.
  • Residence Information View
    • This residence is made up of 11 buildings.
    • Most buildings at this residence have similar access to the one surveyed.
    • The residence surveyed was F Block.
  • Accessible Accommodation Information View
    • There is an/are accessible room(s) within the accommodation.
    • The accommodation has 5 accessible room(s) with accessible bathroom facilities.
    • There is/are 5 accessible room(s) with a ceiling track hoist.
    • The ceiling tracking hoist has full coverage of the room.
    • There is/are 5 accessible room(s) with a wet room/wheel in shower.
    • There is not an/are not adjoining room(s) available for the accessible room(s).
    • Accessible toilet facilities are available.
    • The accessible toilet facilities are located on the ground floor, in the main corridor.
  • Standard Accommodation Information View
    • There is standard accommodation on the ground floor.
    • Ground floor accommodation does have level access.
    • There are standard rooms on other floors.
    • The other floors can be accessed by lift.
    • Standard accommodation has ensuites with stepped shower cubicles.
    • There is not an/are not adjoining room(s) available for the standard room(s).
  • Amenities and Communal Facilities View
    • There is a convenience store within approximately 200 metres of the residence.
    • Communal facilities within this residence include a staffed reception, a launderette, a common room, a recreation room and a study area.
  • Additional Accessibility Aids View
    • There is a deaf alert system available on request.
    • Bed raisers are not available on request.
    • Other auxiliary aids include; Vibration alert devices are available.

Getting Here

Useful Information

Building Parking

  • The building does have its own dedicated parking.
  • Building Car Park View
    • The car park can be used by Blue Badge holders.
    • The car park is located to the left of the main rear entrance.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • Designated Blue Badge parking bays are available.
    • There is/are 3 designated parking bay(s) within the car park.
    • The Blue Badge bay(s) is/are clearly marked and signposted.
    • The dimensions of the designated parking bay(s) are 230cm x 465cm.
    • The Blue Badge parking bays have a marked zone to both sides and rear.
    • The marked zone is 120cm wide.
    • The dimensions of the designated bays do not vary in size.
    • Parking spaces for Blue Badge holders do not need to be booked in advance.
    • The nearest designated bay is 7m (7yd 1ft) from the main rear entrance.
    • The route from the car park to the building is accessible to a wheelchair user.
    • The car park surface is block paving.
  • Site/Campus Car Parks View
    • There is not a site/campus car park within approximately 200m.
  • Public Car Parks View
    • There is not a car park for public use within 200m (approx).
  • On Street Parking View
    • Clearly signed and/or standard marked parking bays are not available.
  • Drop Off Point View
    • There is not a designated drop off point.
  • Comments View
    • There are various standard visitor car parks located around the campus site, for details please refer to the University website.

Outside Access (Reception - Main Front)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to the ground floor of the building and reception.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • There is a dark mat or floor marking at this entrance that might be perceived as a hole.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) automatically (towards you).
    • There is a push pad/button to enter and exit the main automatic doors.
    • The entry push pad or push button is 101cm from floor level.
    • The exit push pad or push button is 106cm from floor level.
    • The door(s) is/are single width with a locked extension leaf.
    • The width of the door opening is 105cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.

Outside Access (Reception - Main Rear)

  • Entrance View
    • This information is for the entrance located at the rear of the building.
    • This entrance gives access to the ground floor of the building and the Reception lobby.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) automatically (towards you).
    • There is a push pad/button to enter and exit the main automatic doors.
    • The entry push pad or push button is 80cm from floor level.
    • The exit push pad or push button is 113cm from floor level.
    • The door(s) is/are single width with a locked extension leaf.
    • The width of the door opening is 102cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.

Outside Access (Laundry)

  • Entrance View
    • This information is for the entrance located at the front of the building, to the left of the main entrance.
    • This entrance gives access to the ground floor of the building and the laundry.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) automatically (towards you).
    • There is a push pad/button to enter and exit the main automatic doors.
    • The entry push pad or push button is 78cm from floor level.
    • The exit push pad or push button is 113cm from floor level.
    • The door(s) is/are single width.
    • The width of the door opening is 105cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.

Outside Access (Upper F Block)

  • Entrance View
    • This information is for the entrance located at the top of F Block.
    • This entrance gives access to Level 2.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is a bell/buzzer.
    • The height of the bell/buzzer is 115cm (3ft 9in).
    • There is an intercom.
    • The height of the intercom is 115cm (3ft 9in).
    • A key fob is required for access at this entrance.
    • The height of the key fob reader is 82cm.
    • The main door(s) open(s) automatically (towards you).
    • There is a push pad/button to exit the main automatic doors.
    • The exit push pad or push button is 115cm from floor level.
    • The door(s) is/are single width with a locked extension leaf.
    • The width of the door opening is 101cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.

Outside Access (Lower F Block - Flats 3-4)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to the lower ground floor lobby.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'F Flats 3 - 4'.
    • There is step-free access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key fob is required for access at this entrance.
    • The height of the key fob reader is 80cm.
    • The main door(s) open(s) automatically (towards you).
    • There is a push pad/button to exit the main automatic doors.
    • The exit push pad or push button is 118cm from floor level.
    • The door(s) is/are single width with a locked extension leaf.
    • The width of the door opening is 104cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.

Outside Access (Upper F Block - Rear Accommodation)

  • Entrance View
    • This information is for the entrance located at the rear upper corner of the building.
    • This entrance gives access to the ground floor of the building, the stairwell and the lift lobby.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key fob is required for access at this entrance.
    • The height of the key fob reader is 115cm.
    • The main door(s) open(s) towards you (pull).
    • The exit push pad or push button is 115cm from floor level.
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 104cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.

Reception

  • Reception View
    • The reception point is located centrally within F Block on the ground floor.
    • The reception point is approximately 5m (5yd 1ft) from the main entrances.
    • The reception area/desk is clearly visible from the entrance.
    • There is step-free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are no windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is not placed in front of a background which is patterned.
    • The lighting levels at the reception point are good.
    • The height of the reception counter is 90cm.
    • There is not sufficient space to write or sign documents on the counter.
    • There is a lowered section of the counter.
    • The height of the lowered section at the counter is 75cm.
    • There is sufficient space to write or sign documents on the lowered section of the counter.
    • There is a clear knee recess beneath the counter.
    • The counter is staffed.
    • Clipboards can be provided to anyone who is unable to use the desk.
    • There is a hearing assistance system at the reception point.
    • The type of system is a portable loop.
    • The hearing assistance system is signed.
    • Staff are trained to use the hearing system.
    • The hearing assistance system was tested by an AccessAble surveyor.
    • The hearing assistance system was tested on 06/06/2024.
    • The type of flooring in the reception area is carpet and tiles.
  • Reception Waiting Area View
    • There is a waiting area close to the reception point.
    • Access to the waiting area is unobstructed.
    • There is a mixture of seating with and without armrests.
    • There is sufficient space for a wheelchair user to use the waiting area.

Getting Around

  • Access View
    • There is step-free access throughout the building via lift(s).
  • Circulation View
    • There are no doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is carpet and tiles.
    • There is some flooring in corridors/walkways which includes patterns or colours which could be confusing or look like steps or holes to some people.
    • There is high visual contrast between the walls and floor in all areas.
    • There is a mixture of seating with and without armrests at regular intervals.
    • The lighting levels are varied.
  • Signage View
    • Wayfinding signage is provided.
    • Floor plans/maps are available.
    • The colour, design and typeface of signs is consistent throughout the building.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.

Laundry

  • The Laundry is located on the ground floor, at the front of the building.
  • The Laundry can be accessed from outside via the automatic door detailed in the Outside Access (Laundry) section, or via the single manual door located in the reception area corridor.
  • All washing machines are located on a lower level, there is also one drier at the same level.
  • Machine door handles are 86cm high, controls are between 95 - 100cm.

Other Floors (Reception Corridor - Upper Entrance)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located at the upper end of F Block.
    • The stairs are approximately 15m from the reception - main front entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • The floors which are accessible by the stairs are G, 1, and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The depth of the steps is 25cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are varied.

Other Floors (Main Staircase)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located in the upper F Block lift lobby.
    • The stairs are approximately 3m from the Accommodation Entrance (Upper F Block - Rear Accommodation).
    • The stairs are clearly visible from the entrance.
    • There are manual, heavy, single doors to enter and exit the stairwell from the first floor upwards.
    • The floors which are accessible by the stairs are G, 1, 2, 3, 4 and 5.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The depth of the steps is 25cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are good.

Lift (Platform - Lower F Block)

  • The lift is located at the lower end of the reception lobby on the ground floor.
  • The lift is clearly visible from the entrance.
  • The lift is approximately 12m (13yd 4in) from the reception - main front entrance.
  • The lift is a platform lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are G and LG.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The visual contrast between the external lift controls and the control plate is high.
  • The visual contrast between the external lift control plate and the wall is high.
  • The clear door width is 90cm (2ft 11in).
  • The dimensions of the lift are 142cm x 165cm (4ft 8in x 5ft 5in).
  • There are separate entry and exit doors in the lift.
  • There is not a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are moderate to good.

Lift (Upper F Block)

  • The lift is located at the upper end of F Block.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 30m (32yd 2ft) from the front main entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are G, 1, 2, 3, 4 and 5.
  • The weight limit for the lift is 1275kg.
  • There are manual, heavy, single doors to access the lift lobby from the first floor upwards.
  • Clear signs indicating the facilities on each floor are provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The visual contrast between the external lift controls and the control plate is medium.
  • The visual contrast between the external lift control plate and the wall is high.
  • The clear door width is 110cm (3ft 7in).
  • The dimensions of the lift are 198cm x 140cm (6ft 6in x 4ft 7in).
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are moderate to good.

Toilet with Adaptations (Ground Floor - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located on the ground floor, in the corridor to the right of reception.
    • This accessible toilet is approximately 20m (21yd 2ft) from the reception - main front entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is tactile, pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is heavy.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 86cm (2ft 10in).
    • The contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 137cm x 2506cm (4ft 6in x 82ft 3in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 80cm (2ft 7in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush, however it is not on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is medium.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is medium.
    • The visual contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is high.
    • The contrast between the walls and floor is medium.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with no lid) disposal units.
    • There is a/are coat hook(s).
    • The height of the coat hook is 144cm from the floor.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf does not have the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 72cm.
    • The shelf is not located where it is reachable.
    • The toilet has a backrest.
    • The height of the toilet seat above floor level is 48cm (1ft 7in).
    • The toilet seat visual contrast is high.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 95cm (3ft 1in).
    • The contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 73cm (2ft 5in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is high.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 100cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 90cm (2ft 11in).
    • The contrast between the hand dryer and the wall is high.

Standard Toilet(s)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The all gender toilet is located on the ground floor of upper F Block.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 19m from the reception - main front entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is medium.
    • There is tactile, pictorial and written text signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 85cm.
    • The wash basin(s) tap type is lever mixer.
    • Lighting levels are good.