Building 13 (Tizard)

University of Southampton, Highfield Campus, Southampton, SO17 1BJ

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Summary

  • Building View
    • Services / Facilities within the building include; Level 1: Design workshop. Level 2: Reception and Administration Offices. Level 3: Workshops, Dynamics and Signal Processing and Control groups. Level 4: The E J Richards Library and Hearing and Balance Centre. Level 5: Aeronautics and Aerodynamics groups.
  • Location of Toilet/Changing Facilities View
    • Accessible toilet facilities are located on Level 2.
    • Female standard toilet facilities are located on Levels 2 and 4.
    • Male standard toilet facilities are located on Levels 2, 3 and 5.
  • Comments View
    • Level 2 is the ground floor.

Useful Information

Getting Here

Generic (Parking Information)

  • Visitors who hold a Blue Badge can park in any parking bay on campus without needing a University parking permit.
    Staff and students should obtain a University parking permit from the University’s parking team, which is free of charge to Blue Badge holders.
    There is a map showing disabled parking bays on Highfield Campus. View information on location of parking spaces.
    If there is not a designated disabled parking bay near to a particular building, then a standard parking bay can be reserved for use by a disabled visitor by contacting parking services on 023 8059 2416. .

Building Parking

  • The building does have its own dedicated parking.
  • Building Car Park View
    • The car park can be used by visitors and staff permit holders.
    • There are no parking charges that apply on the day.
    • The car park is located at the front of the building.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • Designated Blue Badge parking bays are available.
    • There is/are 1 designated parking bay(s) within the car park.
    • The Blue Badge bay(s) is/are clearly marked.
    • The Blue Badge parking bays do not have a marked zone around them.
    • Parking spaces for Blue Badge holders do not need to be booked in advance.
    • The nearest designated bay is 90m (98yd 1ft) from the accessible entrance.
    • The route from the car park to the building is accessible to a wheelchair user with assistance.
    • Assistance may be required because there is / are slopes/ramps.
    • The dropped kerb between the car park and the building does not have tactile paving.
    • The car park surface is tarmac.
  • Public Car Parks View
    • There is not a car park for public use within 200m (approx).
  • Drop Off Point View
    • There is not a designated drop off point.
  • Comments View
    • The Blue Badge Bay is at the rear of the building. Access from the Blue Badge Bay to the main entrance is via a steep slope.

Outside Access (Stepped)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to Levels 1, 2, 3, 4 and 5.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'Institute of Sound & Vibration Research'.
    • There is stepped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key card is required for access at this entrance.
    • The height of the key card reader is 98cm.
    • The main door(s) open(s) automatically.
    • The door(s) is/are double width.
    • The width of the door opening is 112cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) both ways.
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 156cm.
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 11 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 15cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are in the centre of the step(s).
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.
  • Comments View
    • There is tactile paving at the bottom of the two initial steps ahead of the main steps up to the entrance.

Outside Access (Main Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'B13 Tizard Institute of Sound & Vibration Research'.
    • There is ramped/sloped or stepped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key card is required for access at this entrance.
    • The height of the key card reader is 94cm.
    • The main door(s) open(s) automatically.
    • The door(s) is/are double width.
    • The width of the door opening is 113cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • The ramp/slope is located at the front of the building.
    • The gradient of the ramp/slope is steep.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on the right going up the ramp.
    • The lighting levels at the ramp/slope are good.
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 6 step(s).
    • The step(s) is/are not clearly marked.
    • The step(s) has/have tactile paving at the top and bottom.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 16cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides of the step(s).
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.

Getting Around

  • Access View
    • There is step-free access throughout the building via lift(s).
    • There is sloped/ramped access to the West Stairs Level 2 to Level 1.
  • Circulation View
    • There are no doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is vinyl and carpet.
    • There is some flooring in corridors/walkways which is shiny and could cause issues with glare or look slippery to some people.
    • Handrails with a rounded or oval profile are not provided in corridors/walkways.
    • There is high visual contrast between the walls and floor in all areas.
    • There are no seats/chairs at regular intervals.
    • The lighting levels are varied.
  • Signage View
    • Wayfinding signage is provided.
    • The colour, design and typeface of signs is consistent throughout the building.
    • Dementia friendly signage is not provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is not a hearing assistance system in the communal areas of the building.

Other Floors (East Stairs - Level 2 to Level 5)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located to the right from the main entrance.
    • The stairs are approximately 47m from the main entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There is a single (lock leaf) door to access the stairs on Level 3 to Level 5.
    • The floors which are accessible by the stairs are 2, 3, 4 and 5.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 14cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The depth of the steps is 28cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are good.
  • Comments View
    • There is a similar set of stairs on the West side of the building.

Other Floors (East Stairs - Level 2 to Level 1)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located to the right from the main entrance.
    • The stairs are approximately 44m from the main entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, double doors to enter and exit the stairwell on all floors.
    • The floors which are accessible by the stairs are 1 and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on the right going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are not easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are good.

Other Floors (West Stairs - Level 2 to Level 1)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located to the left from the main entrance.
    • The stairs are approximately 13m from the main entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There is a single (lock leaf) heavy door to enter the stairwell on Level 2.
    • The floors which are accessible by the stairs are 1 and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 19cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The depth of the steps is 26cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on the left going up.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are moderate to good.

Lift (Level 2)

  • The lift is located to the right from the main entrance.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 43m (47yd 1in) from the main entrance.
  • The lift is a standard lift.
  • The floors which are accessible by this lift are 1, 2, 3, 4 and 5.
  • The weight limit for the lift is 1125kg.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The visual contrast between the external lift controls and the control plate is high.
  • The visual contrast between the external lift control plate and the wall is high.
  • The clear door width is 107cm (3ft 6in).
  • The dimensions of the lift are 166cm x 120cm (5ft 5in x 3ft 11in).
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are low to moderate.

Ramp(s) or Slope(s) (Level 2)

  • Ramped/Sloped Level Change 1 View
    • There is a ramp/slope located to the left from the main entrance.
    • The ramp/slope is used to access the West Stairs Level 2 to Level 1.
    • The gradient of the ramp/slope is steep.
    • The ramp/slope is permanent.
    • There is not a level landing at the top of the ramp/slope.
    • There is not a/are not handrail(s) at the ramp.
    • The width of the ramp/slope is 147cm (4ft 10in).
    • The lighting levels at the ramp/slope are good.
    • The ramp/slope does not bypass the step(s).

Toilet with Adaptations (Level 2 - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located along the main corridor on Level 2.
    • This accessible toilet is approximately 40m (43yd 2ft) from the main entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 86cm.
    • The contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 130cm x 176cm (4ft 3in x 5ft 9in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The height of the light switch/pull cord is 80cm from floor level.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 76cm (2ft 6in).
    • The transfer space is obstructed by a female sanitary bin and a waste disposal bin.
    • There is a flush, however it is not on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is low.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and clinical waste disposal units.
    • There is a/are coat hook(s).
    • The height of the coat hook is 120cm from the floor.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf has the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 73cm.
    • The shelf is located where it is reachable.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 46cm (1ft 6in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 99cm (3ft 3in).
    • The contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 74cm (2ft 5in).
    • There is a vertical wall-mounted grab rail on the left hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is twist/turn.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 98cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 108cm (3ft 7in).
    • The contrast between the hand dryer and the wall is low.

Standard Toilet(s) (Level 2)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located to the right from the main entrance.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 40m from the main entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is medium.
    • There is pictorial and written text signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 81cm.
    • The wash basin(s) tap type is push.
    • Lighting levels are good.